MotoHawk SAEJ1939 PGN Receive Source Address Set
This block sets up a method that allows the application to change the receivable source address of the referenced PGN.
Block ID
MotoHawk SAEJ1939 PGN Receive Source Address Set
Library
MotoHawk_Protocols_lib
Description
The block will, when executed set the value input to the source address port as the receivable source address for the PGN Rx block by name. Entering a value outside of 0-253 will have no effect on the receivable source address for the referenced PGN Rx block. Providing a value of 1 to the Accept All SA will mean that the Rx PGN block will receive and store for retrieval the referenced PGN from any source address. Setting the Accept all SA port to 0 will allow the PGN to be received by only the source address provided by the source address input port.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Receive PGN Name | String | References the PGN Receive Raw block that will have its acceptable source address changed. |