MotoHawk SAEJ1939 Transmit Complete Trigger
Transmit complete triggers after attempt to transmit J1939 PGN blocks
Block ID
MotoHawk SAEJ1939 Transmit Complete Trigger
Library
MotoHawk_Protocols_lib
Description
This block is triggered upon a successful or failed attempted transmission of a J1939 PGN transmit, J1939 dynamic PGN transmit, or J1939 DM block (example J1939 DM1). The block also returns a pass (1) or fail (0) status of the attempt.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Priority Order | Number | When multiple triggers of the same criteria are present, this specifis which will execute first. The lowest priority trigger will be the trigger that decides the response to the DM11 message. |
This trigger is inside another triggered subsystem | Checkbox | If the trigger is inside another triggered subsystem, this must be checked. |
Trigger even when containing subsystem is disabled | Checkbox | If the trigger is inside another enabled subsystem, then execute this subsystem if that subsystem is enabled. |
Associated Transmit PGN Name | String | This field references the transmit PGN or DM Definition associated with this trigger. |