MotoHawk SAEJ1939 PGN Transmit DM51

This block sets up a DM51 PGN Transmit message using the specified handler.

Block ID

MotoHawk SAEJ1939 PGN Transmit DM51

Library

MotoHawk_Protocols_lib

Description

Outputs all emissions related class C confirmed faults.

The "PGN Definition" script is required to follow the template outlined in the "motohawk_saej1939_dm51tx_example" example file.

The definition script specifies a constant value, a port value, or an external datastore for each input parameter. The location of the block in the application will determine when the port-related information is updated.

This block will not transmit unless the PGN is requested via PGN 59904.

The block will enforce some PGN numbering rules specified in J1939-21. It is required that the application developer become familiar with these rules.

The definition script can optionally add a link to the SPN data required for the Lamp and Flash status contained in DM51.

Block Parameters

Parameter Field Values Comments/Description
PGN Definition String Evaluates to a PGN Transmit DM51 definition specified in the example script.