ADC Periodic Vector Get Status
This block reports the status of the ADC Periodic Vector.
Block ID
ADC Periodic Vector Status
Library
MotoHawk_lib/Analog I/O Blocks
Description
This block has 4 output ports, each of which reports a unique value.
The first port reports the start index of the most recent sampling run. Use this to retrieve the very first sample from the queue.
The second port reports the stop index of the most recent sampling run. Use this to retrieve the last sample from the queue.
The third port reports the total samples recorded in the most recent sampling run.
The fourth port reports sampling is still occurring. Use this to determine whether the data is valid or not.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Name | 'single-quote' enclosed alpha-numeric text | This should be the name of the ADC Periodic Vector System Definition that this block is associated with. |