Analog Input Engineering Units
Transforms raw analog data (either acquired directly by the block or supplied via the input signal) into an engineering value.
Block ID
Analog Input Engineering Units
Library
MotoHawk_lib/Analog I/O Blocks
Description
This block is intended to be used in conjunction with Analog Input Mode block. It transforms raw analog data (either acquired directly by the block or supplied via the input signal) into an engineering value.
The conversion to engineering units is determined by the mode currently specified by the referenced Analog Input Mode block.
The output format is a single precision floating point format in units which are specific to the mode.
The mode in use can be determined via Analog Input Mode State block.
The supported modes are listed here.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Reference Name | Alpha-numeric text, single-quote enclosed | Reference to the Name of the Analog Input Mode block |
Output Port Label (optional) | Alpha-numeric text, single-quote enclosed | Optional label name for the block's output port. |
Data Source | Drop down Analog Input Value Input port |
Selects where the data to be transformed is taken from. |
Number of bits in ADC data | Non-zero Integer | Visible when Input port is selected as the Data Source. Specifies the number of ADC bits (e.g. 12) in the data to be transformed. |