Calibration AutoStore Inhibit

This MotoHawk™ block allows the user to prevent the saving of edited calibration data. This may be desirable if it is known that the power supply is incapable of holding power until the save is complete, or as a method to abort (undo) edits. This feature is only available on DEV modules that store Calibration data on powerdown.

Block ID

motohawk_cal_store_inhibit

Library

MotoHawk_lib/Data Storage Blocks

Description

 

When input port is true, the system is prevented from saving edits to the calibration on power down. This block only has an effect on targets where the calibration is stored in flash and is written on power down. The block does nothing on unsupported targets.

Parameter Field Values Comments/Description
Specify Memory Region Check box (enable) Selects which named region Memory Region Name to apply the inhibit to. This option is only available if the target supports memory regions for calibrations. If unchecked then the input inhibit value is applied to all Calibration regions.
Memory Region Name Alpha-numeric text, single-quote enclosed Name of the memory region to which the inhibit option shall be applied. This option is only available when Specify Memory Region is checked.