MC33810 Spark Command Settings
This MotoHawk™ block allows the runtime tunable settings within the referenced MC33810 device's Spark Command register to be altered.
Block ID
MC33810 Spark Command
Library
MotoHawk_lib/ModuleConfiguration
Description
Overview
This MotoHawk™ block allows the DAC settings of an MC33810 IC to be tuned at runtime. The referenced MC33810 Spark Control Definition block identifies the MC33810 instance that the supplied setting will be applied to.
Signals
Open Secd Time (us)
The MC33810's Open Secondary Timer Threshold. An open secondary fault is detected if the secondary voltage exceeds the diagnostic threshold for longer than the specified time. The time will round to the nearest MC33810 setting of 10us, 20us, 50us or 100us.
End Spark Thresh (mV)
The MC33810's End of Spark Threshold in millvolts. This setting is added to the current battery voltage to determine the End of Spark Threshold voltage. The value will round to the nearest MC33810 setting of 2750mV, 5500mV, 8200mV or 11000mV.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Reference | Alpha-numeric text, single-quote enclosed | The name of the MC33810 Spark Control Definition block that these attributes will apply to. |