Peak/Hold Current Definition
This MotoHawk™ block instantiates a resource to control the Peak and Hold current levels.
Block ID
PeakHold Current Definition
Library
MotoHawk_lib/Advanced Digital I/O
Description
Overview
This MotoHawk™ block instantiates a resource to control the Peak and Hold current levels.
The intent behind the Peak/Hold blocks is to expose the peak/hold behavior of hardware drivers that support dual load current thresholds. The dual current thresholds are nominally set to provide a "peak" current and a "hold" current. The higher "peak" current is initially applied to allow an injector or valve like load to "pull-in". The current requirements to "pull-in" an actuator are higher than the current required to keep an actuator "pulled-in". Thus the current in the load must be "peaked" to achieve "pull-in" and then "held" at a lower threshold to maintain actuator "pull-in".
Some modules support configurable peak and hold levels. This block in conjunction with the Peak/Hold Current Set block allow the user to set a desired current level. Hardware limitations may force the applied levels to be clipped to achievable values. See the Set block for more details.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Name | Alpha-numeric text, single-quote enclosed | Enter a unique resource name. This can be the name of the sensor that is being read. No special characters, such as spaces, dashes, commas (underscore allowed). If no name is given, a name generated that includes the resource name. |
Resource | Drop-down list | Select from available resource listings. |