Tachometer Output
This MotoHawk™ block puts out a train of pulses synchronized to engine RPM, with a variable pulse width, and variable start angle relative to TDC1.
Block ID
motohawk_tachometer
Library
MotoHawk_lib/Advanced Digital I/O
Description
Enter the number of pulses per engine crank revolution. If "Dynamic Create" is checked, this resource will be created the first time this block is executed.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Resource | Drop-down list | Select from available listings, as appropriate. |
Number of Pulses Per Revolution | Numeric | Enter an appropriate value of pulses per engine crank revolution for RPM tracking |
Dynamic Create | Check box (enable) | Select to create this first instance of this resource the first time the block is executed. |
Allow I/O pins to be calibrated | Check box (enable) | Enable calibration and the parameters below. This field is only available on Classic modules, see ModuleTypes for help. |
Name |
Alpha-numeric text, single-quote enclosed |
Choose the Name to reference. No special characters, such as spaces, dashes, commas (underscore allowed). |
Read Access Level | 0-8 | Sets security level 1 lowest, 8 highest, for user access to read value. A setting of zero indicates unsecured access is allowed. |
Write Access Level | 0-8 | Sets security level 1 lowest, 8 highest, for user access to write value. A setting of zero indicates unsecured access is allowed. |
Pin Instrumentation Group | Alpha-numeric text, single-quote enclosed | Defines the desired Folder name and hierarchy to be used by suitable Instrumentation Tools. Use "|" character between folder names to delineate subfolder structure. |
Calibration Parameters Instrumentation Group | Alpha-numeric text, single-quote enclosed | Defines the folder name and hierarchy to be used by a suitable instrumentation tool. Use "|" character between folder names to delineate subfolder structure. |