CAN Over SPI Receive Slot Trigger

This MotoHawk™ block triggers when a message is received on the referenced slot.

Block ID

CAN Over SPI Receive Slot Trigger

Library

motohawk_SPI_lib

Description

Block Parameters

Parameter Field Values Comments/Description
Trigger Name Alpha-numeric text, single-quote enclosed Set the text that will be appended to code generated function name. This is useful when using a difference tool to compare the difference from one build to another. If this is left as an empty cell the appended value will be generated at build time, and can change from build to build.
Reference Slot Alpha-numeric text, single-quote enclosed The Slot Name that this trigger is to be associated with.
Allow placement of trigger inside another triggered subsystem. Check Box (enable) Select to enable trigger inside a triggered subsystem.