MotoHawk OBD Fault Reset XY
This block resets the suspected x/y counts of a fault.
When the reset input is "false", nothing happens. Note that this operation happens asynchronously to the fault definition and fault set blocks, which can update the X/Y counts separately.
Block ID
OBD Fault Reset XY
Library
MotoHawk OBD Fault Manager
Description
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Fault Source | Drop-down List | If "Lookup By Name" is selected, the "Fault Name" parameter is used. If "Input Reference Signal", then the input port is used. |
Fault Name | Edit (optional) | This is the name of an existing fault. |