MotoHawk OBD Global Enable Definition

This block adds the Global Enable state to the OBD Fault Manager.

Block ID

OBD Global Enable Definition

Library

MotoHawk OBD Fault Manager

Description

The Global Enable state allows the user to disable the update of fault conditions and also fault counters (i.e. X of Y). The purpose of this state is to prevent faults from being updated when the system is in an unstable state. For instance, if a module on the network is being reprogrammed, the module will cease to send out communication messages which may cause faults to appear within the system even though the system itself is not failing.

The Global Enable is an optional feature and the OBD Fault Manager will continue to function even if this state is not present. If Global Enable is not present, then the OBD Fault Manager will always be enabled.

Block Parameters

Parameter Field Values Comments/Description
Name String Specifies the name of the VarDec and the Datastore.
Attach a VarDec for Visibility Checkbox If checked, a VarDec is created that shows the current value of the state.
Read Access Level 0-8 Sets security level 1 lowest, 8 highest, for user access to read value. A setting of zero indicates unsecured access is allowed.
Write Access Level 0-8, Read Only Sets security level 1 lowest, 8 highest, for user access to write value. A setting of zero indicates unsecured access is allowed. The parameter can be marked as having no write access with the (Read Only) setting.
Instrumentation Group String Alpha-numeric text, single-quote enclosed Determines Folder name and hierarchy as displayed in instrumentation tools for Pin Group. Use "|" character between folder names to delineate subfolder structure