MotoHawk OBD In Use Performance General Counter Increment

This block increments the General Counter when it is not inhibited.

Block ID

OBD In Use Performance General Counter Increment

Library

MotoHawk OBD Fault Manager

Description

This block increments the General Counter by 1 unless the current value is 65535. If it is 65535, the new value will be 0.

The optional boolean inhibit port can be used to disable the increment operation based on enable conditions.

A General Counter definition block with a name matching the Name parameter on this block must be present.

Block Parameters

Parameter Field Values Comments/Description
Reference Name String This must match the name of a General Counter definition block in the application.
Show inhibit port Checkbox If checked, the inhibit port is displayed. If not, then no port is shown and the block will not be inhibited.