Main Power Relay Control

This MotoHawk™ block provides basic control of the the main power relay, by following the ECUP voltage input pin. 

Block ID

Main Power Relay

Library

MotoHawk_lib/Example Blocks/Main Power Relay Blocks

Description

Main Power Relay

Regardless of where the block is placed in a design, the strategy will execute at the background task rate. This rate is determined by the Trigger Definition block.

Notes

Block Parameters

Parameter Field Values Comments/Description
On Delay Count Numeric value Once the ECU power goes high, this specifies the number of times the background task must execute before the Main Power Relay will be turned on.
Off Delay Count Numeric Value Once the ECU power goes low, this specifies the number of times the background task must execute before the Main Power Relay will be turned off.
ECUP High Threshold Numeric Value Threshold in ADC Counts above which ECUP is considered high
Instrumentation Group Alpha-numeric text, single-quote enclosed Defines the folder name and hierarchy to be used by a suitable instrumentation tool. Use "|" character between folder names to delineate subfolder structure.