This MotoHawk™ block reports the current fault status of the selected CAN resource.
CAN Fault Status
MotoHawk_lib/CAN Blocks
Parameter Field | Values | Comments/Description |
Reference Name | Alpha-numeric text, single-quote enclosed | Reference to CAN Definition to monitor for Faults. This name must exactly match the name specified in the CAN Definition block. |
Show Bus Passive Error Port | Check Box (enable) | Bus Passive is true when the bus is disconnected, shorted, improperly terminated, the baud rate is incorrect, or if bit error rates are high enough to cause hardware failures. |
Show Tx Error Counts Port | Check Box (enable) | "Tx Error Counts" is 0 when the bus is operating properly and increments every time the module is unable to transmit CAN messages. This is usually caused by conflicting message IDs. |
Show Rx Error Counts Port | Check Box (enable) | "Rx Error Counts" is 0 when the bus is operating properly and increments every time the module is unable to receive CAN messages. |