This MotoHawk™ block allows run-time observation of a signal with a suitable Instrumentation tool.
Block ID
motohawk_probe
Library
MotoHawk_lib/Calibration and Probing
Description
The Name Source field allows the name to be entered as a Literal, evaluated as a Matlab expression, or it may be inherited from the name of the input wire. If no name is supplied, (Undefined Name) will be displayed on the block.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Name | Alpha-numeric text, single-quote enclosed | Name assigned to the probe. Should be unique and C-legal (no special characters such as spaces, dashes or commas (underscore allowed). |
Name Source | Select source for Name parameter. | |
Use Parameter | Use Name field text. | |
Input Wire Name | Take name from input wire name. | |
Output Wire Name | Take name from output wire name. | |
Read Access Level | 0-8 | Sets security level 1 lowest, 8 highest, for user access to read value. A setting of zero indicates unsecured access is allowed. |
View Value as | Sets probe data type | |
Number | Numeric value | |
Enumeration | Enables enumeration - maps to the indicated term in the Enumeration text-entry field | |
Text | Text string | |
Enumeration (Cell String, or Struct) | Alphanumeric Cell String, Struct or Script |
Field enabled when Enumeration is selected under "View Value as." Enter
term of defined entity to be mapped. Valid entries are: |
Show Vectors As | Wide Row/Tall Column | Set viewing format for values displayed |
Help Text | Alpha-numeric text, single-quote enclosed | Enter text to describe block usage per needs. |
Units | Alpha-numeric text, single-quote enclosed | Enter text to describe or label units or data for clarification in the Instrumentation Tool, as appropriate per application. |
Row Header Enumeration (Cell String, or Struct) | Alpha-numeric text, single-quote enclosed | Use to identify / locate probe value (see Enumeration) - row header |
Column Header Enumeration (Cell String, or Struct) | Alpha-numeric text, single-quote enclosed | Use to identify / locate probe value (see Enumeration) - column header |
Minimum Value | Numeric Value | Sets the lower end of the expected range for the probe. The specified value is in engineering units (see Engineering Values versus Native Values). |
Maximum Value | Numeric Value | Sets the higher end of the expected range for the probe. The specified value is in engineering units (see Engineering Values versus Native Values). |
Precision | Numeric value, single-quote enclosed | Set the precision of the variable as displayed in the Instrumentation Tool by entering a value '1.x' where "x" is the number of decimal places requested. Default is two decimal places. |
Gain* | Numeric Value | Multiplier component of the conversion equation that converts a native value into an engineering units value (see Engineering Values versus Native Values). |
Offset* | Numeric Value | Offset component of the conversion equation that converts a native value into an engineering units value (see Engineering Values versus Native Values). |
Exponent* | Numeric Value | Exponent component of the conversion equation that converts a native value into an engineering units value (see Engineering Values versus Native Values). |
Instrumentation Group | Alpha-numeric text, single-quote enclosed | Determines Folder name and hierarchy to be used by an Instrumentation Tool. Use "|" character between folder names to delineate subfolder structure. |
*NOTE: Engineering Value = ((Native Value * Gain)^Exponent) + Offset