MotoHawk OBD Fault Set Condition
This block allows the user to set the selected OBD fault condition from the application instead of waiting for the Fault Manager to set or clear it. Variations in OBD regulations require that applications have the control to manually set or clear certain OBD fault conditions. Inputting a 1 into the "Condition" input port will set the selected OBD condition and a 0 will clear the selected condition.
Previous versions of MotoHawk supported a Set Readiness Block. That behavior has been replaced by this block. A checkbox exists to allow this block to emulate the behavior of that block so upgrade will be seamless.
Block ID
OBD Fault Set State
Library
MotoHawk OBD Fault Manager
Description
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Fault Source | Drop-down List | If "Lookup By Name" is selected, the "Fault Name" parameter is used. If "Input Reference Signal", then the input port is used. |
Fault Name | Edit (optional) | This is the name of an existing fault. |
Use set Ready | Checkbox | Checking this option will remove the set/clear functionality and instead will only allow the Ready condition to be set when the inhibit input is false. The primary reason for this checkbox is to allow this block to emulate the "Set Readiness" block that may have existed in models built on an earlier version of MotoHawk. |
OBD Condition | Drop-down List | The OBD condition that is to be set or cleared by the associated input port. Only applicable (and visible) when the Use set Ready option is not checked. |