MotoHawk OBD Mark To Clear
This block allows the user to clear the condition specified by the Fault Condition Criteria parameter. Some OBD regulations allow the conditions to be erased regardless of the normal behavior. This block is intended to satisfy this requirement.
The marking occurs immediately, but the condition will not be cleared until the driving cycle completes. As long as this block executes one time with the inhibit port set to false, the condition will be erased at the end of the drive cycle.
The 'inhibit' port when driven true will prevent the clear action from occurring (no change occurs).
Block ID
OBD Mark To Clear
Library
MotoHawk OBD Fault Manager
Description
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Fault Source | Drop-down List | If "Lookup By Name" is selected, the "Fault Name" parameter is used. If "Input Reference Signal", then the input port is used. |
Fault Name | Edit (optional) | This is the name of an existing fault. |