This MotoHawk™ block allows the runtime tunable settings within the referenced MC33810 device's Spark Command register to be altered.
MC33810 Spark Command
MotoHawk_lib/ModuleConfiguration
This MotoHawk™ block allows the DAC settings of an MC33810 IC to be tuned at runtime. The referenced MC33810 Spark Control Definition block identifies the MC33810 instance that the supplied setting will be applied to.
The MC33810's Open Secondary Timer Threshold. An open secondary fault is detected if the secondary voltage exceeds the diagnostic threshold for longer than the specified time. The time will round to the nearest MC33810 setting of 10us, 20us, 50us or 100us.
The MC33810's End of Spark Threshold in millvolts. This setting is added to the current battery voltage to determine the End of Spark Threshold voltage. The value will round to the nearest MC33810 setting of 2750mV, 5500mV, 8200mV or 11000mV.
| Parameter Field | Values | Comments/Description |
| Reference | Alpha-numeric text, single-quote enclosed | The name of the MC33810 Spark Control Definition block that these attributes will apply to. |
| Copyright 2012 Woodward Corporation. All Rights Reserved. | Visit Us: mcs.woodward.com |