PSP End Trigger

This MotoHawk™ block passes execution control to the application when the selected resource completes a pulse.

Block ID

MotoHawk PSP End Trigger

Library

MotoHawk_lib/Advanced Digital I/O

Description

This MotoHawk™ block passes execution control to the application when the selected resource completes a pulse. This block is supported only when selecting the standard injection sequence type setting on the Injector Sequence Block. Additionally, when using the Spark Sequence Block, this block is supported only when selecting standard and batch sequence types.

Block Parameters

Parameter Field Values Comments/Description
Trigger Name Alpha-numeric text, single-quote enclosed Set the text that will be appended to code generated function name. This is useful when using a difference tool to compare the difference from one build to another. If this is left as an empty cell the appended value will be generated at build time, and can change from build to build.
Resource Drop-down list Select from available listings, as appropriate, to apply output.
Allow placement of trigger inside another triggered subsystem Check box (enable) Allows Simulink to simulate this trigger when it is inside another triggered subsystem.