MotoHawk FPGA Current Drive Profile Definition
This block defines Current Profile which might be used by Current Drive Mux Group Definition block as a reference.
Block ID
Profile Definition
Library
MotoHawk FPGA Current Drive
Description
This block defines a Current Profile to be used by Mux Group Definition block as a reference.
Profiles are enumerated in the system. The Define Enumeration Order option will allow the application to control the order of enumeration via an order value. Enumeration is from lowest to highest.
Xml definition file system path can be defined using an Additional Profile Path block . If not defined default path will be '../../../CurrentProfiles' or '../CurrentProfiles'.
Calibration feature allows some of the Profile parameters to be calibratable. The following parameters can be controlled by calibration: TimeDmd, CurrentDmd, CurrentHysteresis
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Name | Alpha-numeric text, single-quote enclosed | The Name must be unique and will be used by Current Drive Mux Group Defintion block to reference this definition. |
Profile Name | Alpha-numeric text, single-quote enclosed | Profile Name describes the name that exists within the XML definition of the current profile that this block represents. |
Define Enumeration Order | Checkbox | Check to allow the application to control the order that Profiles are enumerated by the system. This can be useful when using calibration tools that deal directly with the value rather than the enumeration. Controlling the enumeration order for all Profiles in the model will ensure that the same value is always associated to the same sensor |
Order | numeric | This value controls how Profiles are enumerated. A low value will enumerate before another Profile that has a higher value. Those Profile that have not checked the Define Enumeration Order will be considered before those Profiles that do have Define Enumeration Order checked |
Allow profile to be calibrated | Checkbox | Allows some of the Profile parameters to be calibrated. |
Read Access Level | 0-8 | Sets security level 0 lowest, 8 highest, for user access to read value |
Write Access Level | 0-8 | Sets security level 0 lowest, 8 highest, for user access to write value |
Instrumentation Group | Alpha-numeric text, single-quote enclosed | Determines Folder name and hierarchy to be used by an Instrumentation Tool. Use "|" character between folder names to delineate subfolder structure. |