MotoHawk FPGA Current Drive Segment Time Measurement

The block outputs segment time measurements

Block ID

Segment Time Measurement

Library

MotoHawk FPGA Current Drive

Description

The block outputs segment time measurements in microseconds which can be used to e.g. calculate kV.

It's possible to focus on a single segment and output a scalar value, or retrieve the full vector of 16 segments using the Segment Selector parameter.

Use the Segment Time Measurement Trigger block to generate a Simulink Function-Call event once the acquisition is ready.

Block Parameters

Parameter Field Values Comments/Description
Reference Output Driver Mode Definition Alpha-numeric text, quote enclosed Associates this trigger with Output Driver Mode Definition.
Segment Selector Drop down list Chooses which segment is to be output. It is possible to output all 16 segments or only one specific segment

Signals

Segment Time

This single precision output signal can be a scalar if one segment is chosen, or a vector of 16 elements if all segments are chosen. Values are provided in microseconds.