VISTA Knock After Noise Calc Mode Set
This MotoHawk™ block controls where the knock calculation is to occur when the pre-configured IIR filter is used.
Block ID
VISTA Knock Knock after Calc
Library
MotoHawk_lib/Knock Blocks
Description
This MotoHawk™ block controls where the knock calculation is to occur when the pre-configured IIR filter is enabled. The setting has no impact on the system when the pre-configured IIR filter is disabled.
Valid values to input into this function are:
0: Knock calculation begins at close of knock integration window.
1: Knock calculation is delayed until after noise calculation if knock window precedes noise window.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Name | Alpha-numeric text, single-quote enclosed | Name of the VISTA knock device to be affected. |