Difference between revisions of "SECM70"
From MotoHawk
Jump to navigationJump to searchm (adding a little bit of detail) |
m (refinement) |
||
Line 4: | Line 4: | ||
===Hardware Features=== | ===Hardware Features=== | ||
:70-Pin platform | :70-Pin platform | ||
− | :Microprocessor: | + | :Microprocessor: ST SPC563M64, 80 MHz |
:Memory: 1.5 M flash, 94 K RAM, 16 K serial EEPROM | :Memory: 1.5 M flash, 94 K RAM, 16 K serial EEPROM | ||
:Operating Voltage: 8–32 Vdc, 36 V (jump start), 5.5 V (crank) | :Operating Voltage: 8–32 Vdc, 36 V (jump start), 5.5 V (crank) | ||
Line 17: | Line 17: | ||
:Up to 2 knock sensors | :Up to 2 knock sensors | ||
''Outputs:'' | ''Outputs:'' | ||
− | :6 injector drivers ( | + | :6 high-impedance injector drivers (up to 4 low impedance injector drivers) |
− | : | + | :Up to 8 electronic spark-triggers for smart injection coils |
:9 low-side drivers | :9 low-side drivers | ||
:3 lamp drivers | :3 lamp drivers | ||
:1 main power relay driver | :1 main power relay driver | ||
:up to 2 H-bridge drivers | :up to 2 H-bridge drivers | ||
+ | :Optional 3-phase brushless DC motor driver | ||
+ | :1 sensor supply (5V) | ||
''Communications:'' | ''Communications:'' | ||
:2 CAN 2.0b channels | :2 CAN 2.0b channels |
Revision as of 09:08, 5 March 2015
Contents
ECM-5634M-70
Hardware Features
- 70-Pin platform
- Microprocessor: ST SPC563M64, 80 MHz
- Memory: 1.5 M flash, 94 K RAM, 16 K serial EEPROM
- Operating Voltage: 8–32 Vdc, 36 V (jump start), 5.5 V (crank)
- Operating Temperature: –40 to +105 °C
Inputs:
- VR or digital crank position sensor
- Digital cam position sensor
- Up to 14 ananlogs
- Up to 5 digital (4 switch, 1 speed)
- up to 2 switch-type oxygen sensors
- Optional wide-range oxygen sensor
- Up to 2 knock sensors
Outputs:
- 6 high-impedance injector drivers (up to 4 low impedance injector drivers)
- Up to 8 electronic spark-triggers for smart injection coils
- 9 low-side drivers
- 3 lamp drivers
- 1 main power relay driver
- up to 2 H-bridge drivers
- Optional 3-phase brushless DC motor driver
- 1 sensor supply (5V)
Communications:
- 2 CAN 2.0b channels
(INCOMPLETE)
Product Summary
The SECM70 control platform fits a variety of applications, including gasoline and natural gas engines for power generation, forklifts, lift trucks, and on-highway vehicles. The SECM70 control is programmed to meet the specific needs of the prime mover and its driven load.
Frequently Asked Questions/Topics
Can I diagnose PWM EST outputs?
Due to the nature of the hardware, EST diagnostics are only available when driven as a sequence and not as a PWM.
The ESTs have a caveat that certain groups must not turn off at the same time as there is shared diagnostic HW.
The groupings where you should avoid turning off at the same time are:
EST 1,2
EST 3,4
EST 5,6,7,8