SECM70

From MotoHawk
Revision as of 09:05, 5 March 2015 by Michael.Vogeli (talk | contribs) (adding a little bit of detail)
Jump to navigationJump to search

ECM-5634M-70

ECM5634M-70.jpg

Hardware Features

70-Pin platform
Microprocessor: Freescale MPC5634, 80 MHz
Memory: 1.5 M flash, 94 K RAM, 16 K serial EEPROM
Operating Voltage: 8–32 Vdc, 36 V (jump start), 5.5 V (crank)
Operating Temperature: –40 to +105 °C

Inputs:

VR or digital crank position sensor
Digital cam position sensor
Up to 14 ananlogs
Up to 5 digital (4 switch, 1 speed)
up to 2 switch-type oxygen sensors
Optional wide-range oxygen sensor
Up to 2 knock sensors

Outputs:

6 injector drivers (3 peak/hold capable)
6 electronic spark-trigger outputs
9 low-side drivers
3 lamp drivers
1 main power relay driver
up to 2 H-bridge drivers

Communications:

2 CAN 2.0b channels

(INCOMPLETE)

Product Summary

The SECM70 control platform fits a variety of applications, including gasoline and natural gas engines for power generation, forklifts, lift trucks, and on-highway vehicles. The SECM70 control is programmed to meet the specific needs of the prime mover and its driven load.

Frequently Asked Questions/Topics

Can I diagnose PWM EST outputs?

Due to the nature of the hardware, EST diagnostics are only available when driven as a sequence and not as a PWM.

The ESTs have a caveat that certain groups must not turn off at the same time as there is shared diagnostic HW.

The groupings where you should avoid turning off at the same time are:
EST 1,2
EST 3,4
EST 5,6,7,8