ISO15765:Blocks:Control DTC Setting Response Set

From MotoHawk
Jump to navigationJump to search

Woodward Custom ISO15765 Control DTC Setting Response Set

This block can be used to accept or deny a request via the ISO15765 protocol to stop or resume the setting of diagnostic trouble codes (DTCs).

Block ID

ISO15765 Control DTC Setting Response Set

Library

Woodward Custom ISO15765

Description

ISO15765ControlDTCSettingResponseSet.png

Provide a value of zero to send a positive response. Provide a non-zero value to deny the request to control the DTC setting.

The ISO15765 protocol responses to be sent in the negative response may be one of:

0x12 Sub-function not supported
0x13 Incorrect message length or invalid format *
0x22 Conditions not correct
0x31 Request out of range
0x33 Security access denied *


* the protocol handler already handles these conditions and returns this negative response appropriately