MotoHawk:Blocks:Knock Definition

From MotoHawk
Jump to navigationJump to search

Knock Definition

This MotoHawk™ block defines parameters of the knock detection and handling.

Block ID

motohawk_knock_def

Library

MotoHawk_lib/Knock Blocks

Description

Knock Definition.PNG

Defines parameter of the knock detection and handling.

Block Parameters

Parameter Field Values Comments/Description
Knock Device Drop-down list Select the knock detect resource
Cylinders [0-12] Numeric Enter number of cylinders
Device Offset from TDC1 Numeric Enter device angle offset from TDC1 (applied to all angle parameters for this block).
Default Sensor Gain 1X/2X Double the incoming signal gain if needed.
Knock Sensor Select [1 per cylinder] Bracket [] enclosed array of values for cylinders, respectively Enter respective cylinder knock sensor select, [0 1 0 1]
PROSAK Mode Drop-down list Select Knock detect mode (see PROSAK CALSETUP description in the PROSAK manual).
Cylinder Increment Rising Edge Location [-360, 360] [dbtdc]* Numeric Indicate Cylinder Increment Rising Edge Location, value ranging from -360 to 360.
Cylinder Increment Falling Edge Location [-360, 360][dbtdc]* Numeric Indicate Cylinder Increment Falling Edge Location, value ranging from -360 to 360.
Cylinder Sync Rising Edge Location [-360, 360][dbtdc]* Numeric Indicate Cylinder Increment Falling Edge Location, value ranging from -360 to 360.
Cylinder Sync Falling Edge Location [-360, 360][dbtdc]* Numeric Indicate Cylinder Sync Falling Edge Location, value ranging from -360 to 360.
Cylinder Ref Window Start
[-360, 360][dbtdc]*
Numeric Indicate Cylinder Ref Window Start, value ranging from -360 to 360.
Cylinder Ref Window Stop
[-360, 360][dbtdc]*
Numeric Indicate Cylinder Ref Window Stop, value ranging from -360 to 360.
Cylinder Knock Window Start [-360, 360][dbtdc]* Numeric Indicate Cylinder Knock Window Start, value ranging from -360 to 360.
Cylinder Knock Window Stop [-360, 360][dbtdc]* Numeric Indicate Cylinder Knock Window Stop, value ranging from -360 to 360.
MKIKS Development Enabled Check box (enable) Apply when needing MKIKS connected to an open module. Initialization will FAIL for a closed module.
Default Filter Coefficients
(-4...4) x20
[] Array of values Enter respective default filter coefficients, 20 values, ranging from -4 to 4. For example [0 0 0 0 1.995 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0].
MotoTune Group String Alpha-numeric text Determines Folder name and hierarchy as displayed in MotoTune. Use "|" character between folder names to delineate subfolder structure.

* dbtdc indicates "degrees before top dead center"