MotoHawk:Blocks:Knock Results
From MotoHawk
Jump to navigationJump to searchKnock Result
This MotoHawk™ block retrieves and supplies knock calculation parameters as outputs, as indicated on block.
Block ID
motohawk_knock_result
Library
MotoHawk_lib/Knock Blocks
Description
Outputs: Cylinder Trigger[12]: A vector of triggers that will occur upon availability of a calculation for a particular cylinder. Last Computed Cylinder: A scalar that indicates the cylinder number of the most recently available data. Knock Energy[12]: The output of the Knock Integrator for each cylinder. RefEnergy[12]: The Reference Integrator output for each cylinder. Ratio[12]: The Ratio output for each cylinder. Refer to PROSAK manual for more information.
Block Parameters
Parameter Field | Values | Comments/Description |
---|---|---|
Knock Device | Drop-down list | Select the knock detect resource. Note that Knock Device 2 is only supported on 128 pin modules. |
Cylinder Firing Order | Numeric [Vector] | A vector of 12 elements in the range of [1,12] to set the firing order of the engine. This will re-order the outputs to be cylinder relative so that KnockEnergy[3] is for cylinder 3 and so-on. |
MotoTune Group String | Alpha-numeric text, single-quote enclosed | Enter a pipe delimited string for the MotoTune group (i.e. 'Diagnostics & Protection | Knock | Knock Setup') |