MotoHawk:Blocks:Knock Results

From MotoHawk
Jump to navigationJump to search

Knock Result

This MotoHawk™ block retrieves and supplies knock calculation parameters as outputs, as indicated on block.

Block ID

motohawk_knock_result

Library

MotoHawk_lib/Knock Blocks

Description

Knock Results.PNG

Outputs: Cylinder Trigger[12]: A vector of triggers that will occur upon availability of a calculation for a particular cylinder. Last Computed Cylinder: A scalar that indicates the cylinder number of the most recently available data. Knock Energy[12]: The output of the Knock Integrator for each cylinder. RefEnergy[12]: The Reference Integrator output for each cylinder. Ratio[12]: The Ratio output for each cylinder. Refer to PROSAK manual for more information.

Block Parameters

Parameter Field Values Comments/Description
Knock Device Drop-down list Select the knock detect resource. Note that Knock Device 2 is only supported on 128 pin modules.
Cylinder Firing Order Numeric [Vector] A vector of 12 elements in the range of [1,12] to set the firing order of the engine. This will re-order the outputs to be cylinder relative so that KnockEnergy[3] is for cylinder 3 and so-on.
MotoTune Group String Alpha-numeric text, single-quote enclosed Enter a pipe delimited string for the MotoTune group (i.e. 'Diagnostics & Protection | Knock | Knock Setup')