Difference between revisions of "112-pin Module Family"

From MotoHawk
Jump to navigationJump to search
(ECM-5644-112 ECM-OH)
(ECM-5554-112-0904)
Line 1: Line 1:
 
There are two ECUs in the 112-pin family - the ECM-5554-112-0904 (PCM-09) and the New ECM-5644-112 (ECM-OH).
 
There are two ECUs in the 112-pin family - the ECM-5554-112-0904 (PCM-09) and the New ECM-5644-112 (ECM-OH).
  
==ECM-5554-112-0904==
+
==[[PCM09|ECM-5554-112-0904]]==
 
[[Image:ECM112.jpg|150px|112-Pin]]               
 
[[Image:ECM112.jpg|150px|112-Pin]]               
  
Line 30: Line 30:
 
:3 CAN buses
 
:3 CAN buses
 
:1 RS485 Channel
 
:1 RS485 Channel
 
  
 
==[[ECM-OH|ECM-5644-112  ECM-OH]]==
 
==[[ECM-OH|ECM-5644-112  ECM-OH]]==

Revision as of 09:15, 25 March 2013

There are two ECUs in the 112-pin family - the ECM-5554-112-0904 (PCM-09) and the New ECM-5644-112 (ECM-OH).

ECM-5554-112-0904

112-Pin

Hardware Features

Microprocessor: Motorola MPC5554, 80 MHz
Memory: 2MB Flash, 64K RAM, + 32K Cache, 32K EEPROM
Calibratible Memory: 512k (256k x2) RAM
Operating Voltage: 9-16VDC, 24V (Jump start), 4.5V (Crank)
Operating Temperature: -40° to 105° C

Inputs

VR and Digital Engine Position Sensor (crank and cam) Inputs
33 Analog Inputs
4 Oxygen Sensor Inputs
3 Speed (digital) Inputs
2 Knock Sensor Inputs
1 Emergency Stop Input

Outputs

8 Injector (high impedance) Outputs
8 Electronic Spark Trigger (5V) Outputs
1 Tachometer or Link Interface Output
14 Low Side Outputs
1 Main Power Relay Driver Output
2 H-Bridge Outputs

Datalinks

3 CAN buses
1 RS485 Channel

ECM-5644-112 ECM-OH

112 Pin ECM-OH

This is our newest module! Check out features and additional information on the ECM-OH wiki page.

These are Preliminary Specifications and subject to change.

Hardware

112-pin platform
Main micro: MPC5644A, 120 MHz
Auxiliary micro: S12G48, 24MHz
Memory: 2M flash, 128K RAM, 32K external serial EE; S12G: 48K flash, 4k RAM, 1.5K EE,
Calibratible micros: MPC5644A, 4M flash, 192K RAM; S12G128, 128k flash, 8K RAM, 4K EE
Operating Voltage: 8–32 Vdc,36 V (jump start), 5.5 V (crank)
Operating Temperature: –40 to +105°C

Inputs

VR or digital crank position sensor
VR or digital cam position sensor
Up to 31 analog inputs
Up to 4 switching oxygen sensors
Up to 2 wide-range oxygen sensors
2 knock sensors
Up to 6 speed inputs

Outputs

8 injector drivers (6 peak/hold capable)
8 ignition coil drivers or spark timer outputs
1 tachometer driver
Up to 19 low-side drivers (1 w/current sense)
1 main power relay driver
2 H-bridge drivers w/current sense
3 sensor supplies (2-5V, 1-12V)

Communications

3 CAN 2.0b buses
1 RS-485 bus