Difference between revisions of "80-pin Module Family"

From MotoHawk
Jump to navigationJump to search
m (Wendy.Bolakowski moved page 80-pin module to 80-pin Module Family without leaving a redirect)
Line 1: Line 1:
 
[[Image:ECM080.jpg|200px]]
 
[[Image:ECM080.jpg|200px]]
 +
 +
For Reference Only - Inactive
  
 
See Product Guide for active part numbers and related hardware.
 
See Product Guide for active part numbers and related hardware.
Line 33: Line 35:
 
:1 RS485 Channel
 
:1 RS485 Channel
  
 +
== Frequency Asked Questions/Topics ==
 +
'''How can I PWM the H-bridges?'''  The only h-bridge that supports PCM is called ETC.  The ESC h-bridge can only be used as a One-Shot or Discrete output
  
 
[[Category:Modules|80-pin Module Family]]
 
[[Category:Modules|80-pin Module Family]]

Revision as of 16:35, 25 March 2013

ECM080.jpg

For Reference Only - Inactive

See Product Guide for active part numbers and related hardware.

Hardware Features

Microprocessor: MPC555, 40MHz
Memory: 448K Flash, 26K RAM, 8K EEPROM
128Kx8 Parallel EEPROM (ECM-0555-080-0703-C)
Operating Voltage: 9-16VDC
Operating Temperature: -40° to 105° C
Sealed connectors operable to 10 ft. submerged.

Inputs

15 Analog Inputs
3 Low Frequency Digital Inputs
1 VR Frequency Input
Up to 2 Hall Effect Frequency Inputs
Dual Sensor Wide Band Knock Detection Input
Dual O2 (Lambda) Sensor
1 Emergency Stop Input

Outputs

12 3A Peak/1A Hold Injector Drivers
8 TTL Level Ignition System Outputs
6 6A Low Side PWM
1 5A Discrete H-Bridge
1 5A PWM H-Bridge
1 Relay Driver (Main Power)
2 1.5 A Low Side PWM

Datalinks

2 CAN 2.0B Channels
1 RS485 Channel

Frequency Asked Questions/Topics

How can I PWM the H-bridges? The only h-bridge that supports PCM is called ETC. The ESC h-bridge can only be used as a One-Shot or Discrete output