MotoHawk:Blocks:Store NonVolatile Data

From MotoHawk
Revision as of 09:30, 11 November 2013 by Wendy.Bolakowski (talk | contribs) (Description)
Jump to navigationJump to search

NonVolatile Store

When this MotoHawk™ block is triggered, all NonVolatile definitions are saved to EEPROM, for later restoration.

Block ID

motohawk_store_nvmem

Library

MotoHawk_lib/Data Storage Blocks

Description

Store NonVolatile Data.PNG

When triggered, all NonVolatile definitions are saved to EEPROM, for later restoration. Note that if your model contains a Main Power Relay block from the Extra Development Blocks library, it will perform this action at controlled shutdown, prior to switching off the relay.

This action stores Data Defined as Non-Volatile only. This would be NV data defined through a Data Definition block, Calibration NV, or Display NV. Calibration data and Fixed Non-Volatile data is stored at a call to the shutdown event only, not through the use of this block.

Block Parameters

This MotoHawk™ block has no user-definable parameters.