MotoHawk:Blocks:Fault Activity Trigger

From MotoHawk
Jump to navigationJump to search

Fault Activity Trigger

This MotoHawk™ block triggers a Simulink Function-Call subsystem, when any Fault changes state as specified.

Block ID

motohawk_fault_activity_trigger

Library

MotoHawk_lib/Fault Management Blocks

Description

Fault Activity Trigger.PNG

The MotoHawk Fault Activity block may be placed into the triggered subsystem, to determine which fault caused this trigger. More than one trigger may be placed in a model triggering off the same event. In this case, the 'Priority Order' can be used to order these independent triggers. If the priorities are the same, then the order is implementation dependent.

Block Parameters

Parameter Field Values Comments/Description
Trigger on Fault Becoming: Pull-down list (Status) Select Status to trigger for (Active, Suspected, etc.)
Priority Order (Lower executes first) Numeric Set priority for Trigger when more than one trigger occurs off the same event.
This trigger is inside another triggered subsystem Check box (enable) Select to enable a trigger within another triggered subsystem.