MotoHawk:Blocks:Time to Nominal Current

From MotoHawk
Jump to navigationJump to search


Time to Nominal Current

This MotoHawk™ block accesses the last observed time to nominal (NOMI) load current diagnostic feedback for the named resource. See Time to Nominal Current Definition for further details.

Block ID

Time to Nominal Current

Library

MotoHawk_lib/Diagnostics

Description

TimeToNominalCurrent.PNG

Signals

Time to Nominal Current (uS)

Recovers the last observed time to nominal current. Typically the block is used within an end of actuation trigger block so that the time can be recovered upon completion of actuation. A negative value (-1) implies that the selected resource did not achieve the nominal load current. Reasons for this include the load being open circuit (a fault condition) or insufficient battery voltage to achieve the specified nominal current. The nominal current is either specified by a different MotoHawk™ block or defined by the hardware. This block does not specify the nominal current.

Block Parameters

Parameter Field Values Comments/Description
Name Alpha-numeric text, single-quote enclosed

This name should equate to [TimetoNominalCurrentDefinition.html Time to Nominal Current Definition] block that this accessor references. No special characters, such as spaces, dashes and commas (underscore allowed)