MotoHawk:Blocks:Time to Nominal Current
Contents
Time to Nominal Current
This MotoHawk™ block accesses the last observed time to nominal (NOMI) load current diagnostic feedback for the named resource. See Time to Nominal Current Definition for further details.
Block ID
Time to Nominal Current
Library
MotoHawk_lib/Diagnostics
Description
Signals
Time to Nominal Current (uS)
Recovers the last observed time to nominal current. Typically the block is used within an end of actuation trigger block so that the time can be recovered upon completion of actuation. A negative value (-1) implies that the selected resource did not achieve the nominal load current. Reasons for this include the load being open circuit (a fault condition) or insufficient battery voltage to achieve the specified nominal current. The nominal current is either specified by a different MotoHawk™ block or defined by the hardware. This block does not specify the nominal current.
Block Parameters
Parameter Field | Values | Comments/Description |
Name | Alpha-numeric text, single-quote enclosed |
This name should equate to [TimetoNominalCurrentDefinition.html Time to Nominal Current Definition] block that this accessor references. No special characters, such as spaces, dashes and commas (underscore allowed) |